Electric Boiler
Thermal Storage Solutions
With 100–5000 liter storage and 2–120 kW heater options, it scales from residential to heavy industrial facilities.
About the Electric Boiler
With 100–5000 liter storage and 2–120 kW heater options, it scales from residential to heavy industrial facilities.
It requires no external boiler, flue, or gas line; immersion heaters convert electrical energy into heat and keep the water ready at the set temperature.
What Is an Electric Boiler?
Immersion heaters bring the water to the set temperature; strong insulation keeps heat in the tank for a long time so the unit does not run continuously unnecessarily.
Operating Principle
A Legionella protection program periodically raises the water to a high temperature to support hygiene; residual-current and over-temperature protection ensure safe operation.
Independent Operation and Flexible Installation
It eliminates the need for a central heating system or flue connection.
Safe and Clean Energy
Because it does not use natural gas, LPG, or fuel oil, there is no gas-leak or carbon-monoxide risk; it produces no flue gas or combustion emissions. It provides emission-free, quiet, and clean hot water in enclosed spaces and is preferred in green-building and environmentally conscious projects.
Key Features
- PROWATT series: 100–5000 L storage; 2–120 kW heaters per customer request.
- S235JR construction; DIN 4753-3 enamel + magnesium anode (cathodic protection).
- Max. operating pressure 10 bar; max. operating temperature 95 °C.
- Separate control for each heater; long life and balanced operation.
- ProWatt B control panel: LCD (TR/EN), residual-current / voltage / current protection, Legionella program, building-automation integration.
- High-density polyurethane insulation; Termowen or vinyl outer jacket.
- Operates on electricity alone; optional water coil or plate heat exchanger for hybrid operation.
- Designed to TS EN 13445-3; pre-delivery pressure test at 1.3× design pressure.
Installation and Commissioning
During commissioning, pressure testing, thermostat/panel settings, and safety functions are verified. The Tanpera technical team provides on-site support and training.
After-Sales Services
The Tanpera service network supplies magnesium anodes, heaters, gasket sets, and control-panel spare parts throughout the project life. Annual authorized service maintenance, anode inspection, and scale management protect tank hygiene and heating performance.
- Magnesium anode and heater supply
- Periodic maintenance and tank cleaning planning
- Commissioning, training, and on-site technical support
- Control-panel fault diagnosis and operating recommendations
Frequently Asked Questions
It is a storage hot-water heater that operates on electricity only. Immersion heaters heat the water; a thermostat or ProWatt panel maintains the target temperature. No external boiler or flue is required; it is offered in the 100–5000 L and 2–120 kW ranges.
It is used in homes without gas infrastructure, commercial spaces such as gyms / restaurants / salons, factories and communal shower facilities, hospital and food-process water, green-building projects, and hotel/hospital backup hot-water needs.
Storage and kW are calculated from number of people/showers, target temperature, mains inlet temperature, and usable tank ratio. In the brochure example, PROWATT 1000/10 – 3x15 is selected for a 30-person shower scenario. Tanpera engineering sizes each project specifically.
Maximum operating pressure is 10 bar; maximum operating temperature is 95 °C. The typical set range is 30–85 °C. Units are tested at 1.3× design pressure before delivery.
It offers IP 54 protection, TR/EN LCD menu, real-time programming, temperature/voltage/fault readout, residual-current plus high-low voltage and high-current protection, a Legionella program, and operating/fault signaling to building automation.
100–1000 L: 50 mm, 42 kg/m³ rigid polyurethane + Termowen cladding. 1500–5000 L: 80 mm, 18 kg/m³ open-cell soft polyurethane + vinyl jacket. This construction reduces standby losses.
Annual authorized service maintenance, magnesium anode inspection/replacement, and scale management are recommended. The anode is a consumable. Domestic water must comply with regulations; excessive hardness shortens heater life. A TS EN 1487 safety valve is mandatory at installation; the tank must not be heated when empty.
Yes. In addition to electricity-only operation, efficient hybrid operation with other energy sources is possible by adding a water coil or plate heat exchanger. Non-standard accessory and insulation options are available on request.
You can download or view the English brochure and user manual as PDFs from the Documents tab on the product page.
Submit your project details via the Quote Form on the product page, or contact our sales team at sales@tanpera.com.